PRIMOR 1000 / 1600

Turning the safe handle triggers a sequence of events in locks with swing bolts. The handle sets the boltwork in motion, which pushes the lock bolt aside with its locking edge and thus enables the cabinet to be opened immediately.

Bolt drive
Indirect drive by moving the boltwork to the open or closed position closed position
Bolt design
Spring-loaded swing bolt, can be swung to the left or right
Fastening
Standard mounting dimensions, 3 screw-on points
Installation positions
Right / Left / Top / Bottom
Drill protection
Integrated
Plug connection
- PRIMOR 1000: Post connector

- PRIMOR 1600: Molex PICO-SPOX
Power supply
- PRIMOR 1000 / 1600: Battery operation

- PRIMOR 1000: External operation, e.g. via intruder alarm system (prerequisite: PrimorSIGNAL or PrimorSIGNAL+ signal box)
Innovations PRIMOR 1600
- Integrated drill protection
- Simplified cable routing
- Very low idle stroke
PRIMOR 1000 PRIMOR 1600
User codes
9
1
Master codes
1
1
Instant opening code
Operating lock
False code lock
Opening delay time
1 - 99 min
1 - 99 min
Opening hours
1 - 19 min
1 - 19 min
Silent alarm*
Remote lock*
Audit - without date and time**
100
Battery monitoring
* Prerequisite: PrimorSIGNAL / PrimorSIGNAL+ signal box
** Requirement: PrimorAUDIT software
Item number Article description
P-1000-00-00
Lock PRIMOR 1000, system cable
P-1600-01-00
Lock PRIMOR 1600, system cable
P-SIGNAL
PrimorSIGNAL signal box, Y-adapter, system cable (only suitable for PRIMOR 1000)
P-SIGNAL-PLUS
PrimorSIGNAL+ signal box, system cable (only suitable for PRIMOR 1000)
P-AUDIT
PrimorAUDIT software (download), iButton reader, iButton, USB adapter, Y adapter, system cable (only suitable for PRIMOR 1000)

Other products in the series

Accessories

Certification

PRIMOR 1000
✓ EN 1300 B
✓ VdS class 2
✓ ECB-S
✓ IMP Class B

PRIMOR 1600
✓ EN 1300 B
✓ VdS class 2
✓ ECB-S
✓ A2P level B
✓ SBSC

Field of application

Secure storage units according to
EN1143-1 Grade 0 - V